NEW: Adapters for Interfacing DSI Telemetry Transmitters with PowerLab
|
|
 |
 |
Researchers can now acquire and analyze small animal signals recorded by DSI telemetry equipment with PowerLab data acquisition and analysis systems. The new adapters convert small animal digital telemetry signals from DSI transmitters to AC coupled analog voltage signals. The adapters interface the analog signal with PowerLab systems through a BNC connection.
Using the adapters, data can be collected simultaneously as:
- a digital signal by the DSI Data Exhange Matrix unit with Dataquest ART software
- an AC Coupled Analog Voltage signal by PowerLab data acquisition systems with LabChart (or Chart) software
Above: Example equipment set-up for acquiring an ECG signal to both a Data Exchange Matrix and PowerLab system. Each adapter must be interfaced with a DSI new generation receiver – either an RPC-1 (plastic cage receiver) or RMC-1 (metal cage receiver).
The following signals can now be interfaced with PowerLab systems:
Signal |
Compatible Transmitters |
Adapter |
Other Equipment Available from ADInstruments |
| ECG |
• EA-F20 • ETA-F20 • CA-F40 • CTA-F40 • CTA-D70 |
273-0008-001 Analog ECG Output Adapter (Model: Option R08)
|
272-6001-001 RPC-1 Receiver |
| Temperature |
• TA-F20 • TA-F40 • TA-F50 • ETA-F20 • CTA-F40 • CTA-D70
|
273-0016-001 Analog Temperature Output Adapter (Model: Option R12)
|
272-6001-001 RPC-1 Receiver |
| Blood Pressure |
• PA-C10 • PA-C40 • PA-D70 |
273-0017-001 Calibrated Pressure Analog Adapter (Model: R11CPA)
|
272-6001-001 RPC-1 Receiver
275-0020-001 Ambient Pressure Reference (Model APR-1) The APR-1 unit provides the atmospheric pressure signal. This allows the R11CPA to produce a gauge pressure signal from an absolute pressure signal.
E13659(110/220) Power Supply (can be used to provide power to the R11CPA Analog Adapter in the absence of a Data Exchange Matrix or BCM100) |
| Time-Multiplexed Telemetry Signals |
• F20-EET • F40-EET
|
273-5004-001 Multichannel Receiver Decoder (Model: DL10 Analog Adapter) The DL10 converts the multiplexed signal into up to 3 individual analog voltage signals (eg, biopotential, pressure, temperature)
|
272-6001-001 RPC-1 Receiver
E13659 (110/220) Power Supply (can be used to provide power to the DL10 Analog Adapter in the absence of a Data Exchange Matrix or BCM100)
|
| Activity |
• PA-C10 • PA-C40
|
273-0017-001 Calibrated Pressure Analog Adapter (Model: R11CPA) OR 273-5004-001 Multichannel Receiver Decoder (Model: DL10) |
MLAC28 DSI Animal Activity Adapter Kit
E13659 (110/220) Power Supply (can be used to provide power to the R11CPA or DL10 Analog Adapter in the absence of a Data Exchange Matrix or BCM100)
| Please note that ADInstruments does not sell DSI transmitters, RMC-1 Metal Cage Receivers, Data Exchange Matrix units, or BCM100 units.
Please consult your ADInstruments representative before making any purchasing decisions to ensure you have the equipment configuration required to complete your application.
Advanced Analysis With LabChart ModulesOnce the telemetry signals have been acquired by PowerLab systems with LabChart, they can be analyzed using the advanced analysis features in LabChart Modules, including:
04 April 2008
|