Since 1974, Dagan Corporation has been developing and manufacturing innovative scientific instruments for the electrophysiology and neuroscience markets. Their product range includes Whole Cell Clamps, Patch Clamps, Single and Two Electrode Voltage Clamps, Intracellular and Extracellular Preamplifiers, High Impedance Headstages and accessories.
ADInstruments supplies the complete range of Dagan products for intracellular and extracellular neurophysiological research. Contact your ADInstruments representative for more details. Below is a sample product selection.
|
 |
Research Systems |
 |
|  |
ML870B70 Extracellular Recording System | A system for making extracellular recordings using high-impedance microelectrodes and a high gain, low noise neutralized preamplifier. |
 |
|  |
ML870B71 Intracellular Recording System | A dual channel system for single and dual channel intracellular recordings along with current injection. |
 |
|  |
ML870B72 Two Electrode Voltage Clamp System | The Two Electrode Voltage Clamp System contains 3 low-noise headstages and channels with bridges for current passing and capacitance compensation. |
 |
Instruments |
 |
|  |
TEV-200A Two Electrode Voltage Clamp | A high-performance two electrode clamp. |
 |
|  |
2400A Extracellular Preamplifier | A low noise, high gain extracellular preamplifier |
 |
|  |
IX2-700 Dual Intracellular Preamplifier | A dual channel microelectrode preamplifier suitable for intracellular and extracellular recordings. |
 |
|  |
IX1/115 Single Channel Intracellular Preamplifier (IX1/115) | A single channel intracellular recording preamplifier |
 |
|  |
EX1/115 Single Channel Differential Amplifier (EX1/115) | A single channel differential extracellular preamplifier |
 |
|  |
EX4-400 Quad Differential Amplifier | A four channel differential extracellular preamplifier |
 |
|  |
AM-2 Audio Monitor | The AM-2 converts electrical signals into sound. |
 |
|  |
EX1/220 Single Channel Differential Amplifier (EX1/220) | A single channel differential extracellular preamplifier |
 |
|  |
IX1/220 Single Channel Intracellular Preamplifier (IX1/220) | A single channel intracellular recording preamplifier |
 |
|  |
BVC-700A Whole Cell Clamp (Bridge & Voltage Clamp Amplifier) | A cost-effective amplifier for ultra high speed Patch Pipette Current Clamping. |
 |
|  |
PC-ONE Patch/Whole Cell Clamp | The PC-ONE is a Patch Clamp, designed to be easy to use and very cost effective, offering a wide range of capabilities for any research laboratory |
 |
|  |
CELL CLAMP 2-V Two Electrode Clamp | An ideal low cost solution for two electrode voltage clamping where multiple setups are required classroom. |
 |
|  |
BSI-950/115 Biphasic Stimulus Isolator (BSI-950/115) | An economical stimulus isolation unit capable of producing biphasic current and voltage stimulation. |
 |
|  |
BSI-950/220 Biphasic Stimulus Isolator (BSI-950/220) | An economical stimulus isolation unit capable of producing biphasic current and voltage stimulation. |
 |
Transducers and Accessories |
 |
|  |
TEV-201 Headstage (for TEV-200A) | A high impedance low noise headstage for voltage clamp studies. |
 |
|  |
2410A Capacitance Compensation Probe | A low noise high impedance headstage probe. |
 |
|  |
7001/N Headstage (for IX2-700) | An intracellular headstage probe. |
 |
|  |
4001 Extracellular Differential Headstage (w capacitance comp.) | A differential headstage probe for use with the EX1 and EX4-400 Extracellular amplifiers. |
 |
|  |
4002 Extracellular Differential Headstage (w/o capacitance comp.) | A differential headstage probe for use with the EX1 and EX4-400 Extracellular amplifiers. |
 |
|  |
8024-15 Extracellular Headstage | An extracellular headstage which can be used with intracellular amplifiers such as IX1, IX2-700 or TEV-200A. |
 |
|  |
8024-7001 Dual Mode Extra/Intracellular Headstage | A headstage probe for both extracellular and intracellular recordings using an intracellular preamplifier. |
 |
|  |
TEV-208 Series Resistance/Leakage Current Adapter Box | Compensates for series resistance and leakage current. |
 |
|  |
BUZ-1 Universal Buzz Box | A device for impaling/rupturing cells in intracellular recordings. |
 |
|  |
BUZZ Foot Pedal Buzz | A foot pedal to control impaling of cells used in intracellular recordings. |
 |
|  |
HB120 Glass Pipette Holder (1.0 - 1.2 mm) | A glass pipette holder for use with electrophysiology headstages. |
 |
|  |
HB180 Glass Pipette Holder (1.5 - 1.8 mm) | A glass pipette holder for use with electrophysiology headstages. |
 |
|  |
PS-1 Power supply for 220-240V AC | A power supply for use with Dagan equipment and 220-240V mains power |
 |
| |
8018 Headstage Extension Cable (universal 15 pin, 3m) | Cable extension for headstages |
 |
| |
PC-ONE-(10-80) PC-ONE Headstages | A selection of headstages for use with the PC-ONE Whole Cell Patch Clamp. |
| |