MPVS Ultra Pressure-Volume Unit (large & small animals)

MPVS Ultra Pressure-Volume Unit (large & small animals)

Overview:

The 880-0168 MPVS-Ultra Pressure-Volume Unit can be used in the measurement of  ventricular pressure and volume in small (mice, rats) through to large animals (dog, sheep, pig). The unit provides analog outputs via BNC connectors for direct connection to a PL3516/P PowerLab 16/35 (includes LabChart Pro Modules) for two pressure channels and seven selectable volume channels.

Includes:

  • US or European power cord, USB cable
  • User manual and MPVS Ultra training CD
  • MPVS Ultra Control software

Purchased separately:

  • Pressure-volume catheters (see below for suitable catheters)
  • 880-0169 MPVS Ultra Cable pack (10ft) (required for connecting PV catheters to the MPVS Ultra Pressure-Volume Unit).  Includes:
    • 1x CEC-10E PV Extension Cable (10') for volume determination and
    • 1x PEC-10D Pressure Extension Cable (10') for pressure measurement.
  • 880-0172 MPVS Ultra BNC Cable pack (required for connecting the MPVS Ultra Pressure-Volume Unit to the PowerLab) Includes:
    • 10 x BNC-BNC 9" cables
    • 2 x BNC-BNC 3' cables
    • 1 x BNC-BNC 1' cable
  • 001-1056 PVAN Ultra analysis software
  • 910-1060 Rho Calibration Cuvette kit


This unit is recommended for measuring ventricular pressure-volume in hearts from mice and rats through to sheep and pigs using any of the following Pressure-Volume catheters.

Multi Segment PV Catheters (dog/pig/sheep)
880-0168 MPVS Ultra Pressure-Volume Unit is included in ADInstruments PL3516B49 MPVS-Ultra Foundation System.

The Pressure-Volume catheters listed above are to be purchased separately for use with this system. For more information or assistance please contact your nearest ADInstruments representative.

 

Note: VENTRI-CATH catheter series require the additional purchase of CEC-10PV PV Extension Cable (VC to MPVS Ultra, 10ft) to connect to the 880-0168 MPVS-Ultra Pressure-Volume Unit (large and small animals).

Multi Segment PV Catheters (rabbits/cats)

Single Segment PV Catheters (mice/rats)

The

Features:

  • Analog outputs for two pressure signals and selectable volume outputs to easily integrate with PowerLab and LabChart.
  • State-of-the-art technology
  • Can be used with small and large animals
  • Flexible volume determination using selectable catheter segments
  • Built-in volume calibration technique using Rho cuvette and Baan’s equation
  • Software-controlled user interface
  • Adjustable gain settings to allow both in vivo and in vitro studies
  • Dual pressure inputs
  • Seamless integration with PowerLab and LabChart
  • Compatible with all Millar Mikro-Tip P-V Catheters

Applications:

The MPVS Ultra™ unit simultaneously and continuously measures high-fidelity left ventricular pressure and volume from the intact beating hearts of animals, from transgenic mice through to domestic livestock. Common applications include:
  • Baseline P-V loop analysis
  • Occlusion P-V loop analysis
  • Phenotyping gene manipulations
  • Monitoring of cardiac failure or hypertrophy
  • Cardiovascular remodeling
  • Pharmacology and toxicology
To read more about this application see the Ventricular Pressure-Volume page.