Four Channel Differential Amplifier

Four Channel Differential Amplifier

Overview:

The DP-304-V Four Channel Differential Amplifiers and AC/DC differential pre-amplifier are highly suited for EEG, EKG and extracellular recording.

 

  • IC-2S Input Cable set for DP-304-V (2 pack)
  • IC-4M Input Cable set w/alligator clip for DP-304-V (2 pack)


Note: Please specify V=115 or V=220 mains power

 

Accessories:

Features:

  • High input impedance
  • High common mode rejection
  • Low noise with high gain
  • High tolerance to DC baselines
  • Bandwidth filtering available

High Input Z, High CMR

High common mode rejection is very important in minimizing electrical interference. The high input resistance of the DP-304-V (1012 Ω typical) ensures that the instrument's high CMR will not be degraded by differences in source impedance at the input. This is important in extracellular recording, where the difference in resistance of the recording and indifferent electrode is often large.

High DC Tolerance
Extracellular action potentials are typically measured in microvolts but are usually accompanied by much larger DC electrode voltages. The DP-304-V is designed to amplify these microvolt level events with as much as ±3 VDC at the input.

High Gain, Low Noise and Bandwidth Limiting
Gain selections at x100, x1000 and x10000 are available. Thus even microvolt signals are sufficiently amplified for computer and recorder inputs. Noise is very low, typically 10 µV p-p at 1 Hz to 10 kHz bandwidth. Reducing the bandwidth with the low pass and high pass filters further lowers noise.

Calibration Signal
The internal Cal signal provides a convenient check of amplifier gain and operation.

Rack Mountable
The DP-304-V is housed in a rack mounting cabinet and is line powered.

Input Cables
The standard IC-2S input cables (2 per channel) are not terminated at the outboard end. Optionally available are cables with 2 mm pin and alligator clip (p/n IC-4M). There is no additional cost if specified at time of order.

Summary of Features:
  • Four channel AC/DC pre-amplifier designed for amplifying weak signals such as EEG, EKG and extracellular action potentials. Inputs switched ON or OFF individually
  • Powered by 110 to 130 VAC at 60 Hz or 220 to 240 VAC at 50 Hz with 10 V/A
  • Very low noise with 10 µV peak-to-peak (1 Hz to 10 kHz with input shorted)
  • High gain with selections of x100, x1000 and x10000. Microvolt level signals are sufficiently amplified for computer data acquisition and signal analysis
  • Excellent common mode rejection of 100 dB min (100000:1) at 60 Hz with input resistance 1012 Ω typical
  • Both high pass and low pass filters, each with 4 switch settings
  • Low Frequency (high pass) Filter Settings: 0.1, 1.0, 10 & 300 Hz
  • High Frequency (low pass) Filter Settings: 0.1, 1.0, 3.0 & 10 kHz
  • DC offset of ±600 mV at output BNC operates in both AC or DC modes
  • A front panel calibrate push button applies 1 mV pulse to the amplifier input to check intermediate gains and support equipment

Applications:

The Four Channel Differential Amplifier allows recording of EEG, EKG and extracellular recording which include:
  • Single Unit Recording – records the electrical activity of a single one neuron with a small tip electrode 
  • Multi-Unit Recording – records electrical activity generated by several neurons
  • Field Potentials - records the field potential generated from indistinguishable activity generated by many cells
  • Amperometry - records changes in the chemical composition of the oxidized components of a biological sample using a carbon electrode
For more information see the Extracellular Recordings and Neurophysiology application pages.

Specifications:

  • Voltage Gain, AC/DC: x100, x1,000 and x10000
  • Input Resistance: 1012 Ω typical
  • Leakage Current: 50 pA typical
  • Common Mode Rejection: 100 dB min (100000:1) at 60 Hz
  • Noise, input shorted: 10 µV p-p, 1 Hz to 10 kHz
  • Low Frequency Filter Settings (high pass): 0.1, 1.0, 10 and 300 Hz
  • High Frequency Filter Settings (low pass): 0.1, 1.0, 3.0 and 10 kHz
  • Calibration Signal: 1 mV p-p at 10 Hz
  • Max. Common Mode Signal: ±3 V
  • Output Voltage Swing: ±10 V
  • Output Resistance: 220 Ω
  • Input and Output Connectors: BNC
  • Power Requirements: 115 or 230 VAC, 50 or 60 Hz
  • Physical Size: 17.8 x 43.2 x 25 cm (H x W x D)
  • Shipping Weight: 6.8 kg
  • Warranty: Three years, parts and labor