Stimulus Isolator

Stimulus Isolator

Overview:

The ML1101 Stimulus Isolator insulates the output for the ML1001 Electronic Stimulator from ground. This minimizes the area of stimulation to ensure greater precision, while reducing stimulation artifacts and facilitating the observation of evoked action potentials.  The ML1101 can only operate with a stimulator and is configured for use with the ML1001 Electronic Stimulator.

Features:

  • Numeric power indication: Indicates the amount of power that goes through the device.
  • Constant-voltage/current output of both positive and negative polarity: The device can output the biphasic wave constant voltage that is essential for evoked action potential induction during experiments with cells and other samples.
  • Excellent input and output linearity: The output changes linearly with respect to the amplitude of the input signal.
  • Built-in over current alarm: An alarm is generated when the electrode resistance of the load is too large for the set current to pass.

Applications:

For use with the ML1001 Electronic Stimulator for:
  • Neurophysiology
    • Patch clamping
    • Extracellular recording
    • Nerve fiber – action potentials
  • Muscle and isolated myocyte studies
    • Skeletal Muscle
    • Smooth Muscle
    • Cardiac Muscle

Specifications:

Input specifications
  • Maximum input amplitude: ±10 V or less
  • Input connector: 10-pin connector

Isolation method
  • Analog signal transmission through hot coupler

Constant-voltage section

  • Rough adjustment: 0.1, 1, 10 V (3-step adjustment)
  • Fine adjustment: Control for continuous adjustment of all ranges
  • Magnification meter: ×1 to ×10 (23-step control)
  • Output maximum current: 10 mA
  • Output impedance: 200 Ω or less (2 kΩ or less in the 1 V range)
  • Pulse response: 10 μs or less rising for all ranges
  • Excessive deviation: 5% or less for all ranges

Constant-current section

  • Rough adjustment: 10 μ, 100 μ, 1 m, 10 mA (4-step adjustment)
  • Fine adjustment: Control for continuous adjustment of all ranges
  • Pulse response: 10 μs or less (RL = 10 kΩ) rising for all ranges
  • Excessive deviation: 5% or less for all ranges

Output current characteristics
  • Output insulation: Between output terminals and cabinet 100 MΩ or more (500 DC V)
  • Stray capacitance: Between output terminals and cabinet 150 pF or less
  • Display Indication: 3-digit LED indication + unit
  • Accuracy: 5% or less
  • Output polarity switch Provided
  • Output OFF function STIM ON/OFF switch Provided
  • OVERLOAD detection function Provided
  • An alarm is generated when the guaranteed range of stimulation current is exceeded.

Environmental Conditions
Usage environment conditions:
  • Operating temperature range: 10 to 40ºC
  • Operating humidity range: 30 to 90%
  • Atmospheric pressure: 70 to 106 kPa
Storage environmental conditions:
  • Storage temperature range: -20 to 65ºC
  • Storage humidity range: 10 to 90%
  • Atmospheric pressure: 70 to 106 kPa

Usable Life
  • 6 years (based on self-certification of company data)

Safety Classification
  • Degree of protection against harmful ingress of liquids: IPX0 (devices without special protection)
  • Degree of protection against flammable anesthetic gas Not protected (unsuitable)
  • Mode of operation: Continuous operation

Dimensions and Mass
  • Dimensions: 160 (W) x 100 (H) x 250 (D) mm
  • Mass: 2 kg

Electromagnetic compatibility
  • IEC60601-1-2 :2001 (when connected to 1001)