Start recording experimental data just seconds after opening LabChart.

Welcome Center

The Welcome Center for LabChart 7 provides structured, easy and quick access of LabChart resources and materials. Features of the Welcome Center include:

  • Gallery Panel: Access to ADInstruments resource files or user-defined files
  • Recent Files Panel: Up to 100 recently assessed files can be displayed. You can choose to open any of the files, clone settings from a file or open a new document
  • The ADIPak mechanism integrates with Windows Explorer to allow easy packaging and installation of content into Welcome Center. Creation of custom ADIPak files is simple. Files can be easily shared with colleagues, collaborators or students.
  • LabChart 7 Welcome Center Welcome Center showing the Recent Files Panel and Getting Started content

    Download Tip  Download: Welcome Center Software Tip(268 KB)


    ADIPak Creator Dialog ADIPak Creator Dialog showing the easy one-step process to package data files and other LabChart resources

    Input Amplifier

    In the Input Amplifier window you can:

    • Preview an incoming signal and optimize data collection parameters
    • Select an appropriate range
    • Shift and stretch the vertical amplitude axis to make the best use of the available display area
    • Remove unwanted drift and noise with high pass and low pass filters
    • Change the polarity of the signal and display the offset
    Input Amplifier Dialog Input Amplifier Dialog

    Easy Units Conversion

    Convert the input voltage signal to useful units using the Units Conversion dialog. Any signal can be viewed in units such as mA, mmHg, pH or g, or as a custom defined unit, after performing a linear calibration. Different unit scaling can be applied to each channel. The unscaled raw data is always retained and available for recall at anytime. For non-linear sensors, multipoint calibration (up to twelve points) can be performed with the Multipoint Calibration Extension.

    Units Conversion Dialog Units Conversion Dialog

    Change Channel Settings in Seconds

    LabChart offers 32 channels with variable sampling speeds. Use the Channel Settings dialog to set up multiple channels quickly from one location.

    • Label channels with titles
    • Turn channels on or off
    • Adjust the input range
    • Configure each channel's Input Amplifier dialog
    • Change the color of the data trace
    • Turn the channel separator on or off
    • Select channel calculations
    The Channel Settings dialog allows access to a range of dialogs for quick and easy set up of channel parameters The Channel Settings dialog allows access to a range of dialogs
    for quick and easy set up of channel parameters

    Triggering and Scope View Sampling

    Users can control how and when LabChart starts and stops recording using the triggering options in the Sampling dialog. You can use the controls to set up the type of trigger event, any delay before recording, how many times to repeat triggering and how multiple blocks in Scope View are handled. You can start and stop a recording using an external trigger source, stimulator or by setting a threshold voltage to trigger from one of the recording channels. Pre-triggering and post-triggering options are available.

    Sampling (left) and External Trigger Options (right) dialogs Sampling (left) and External Trigger Options (right) dialogs

    Quick Stimulation Set-up

    The software-controlled Stimulator allows you to generate a stimulus or series of stimuli (pulsed or stepped waveforms) from the PowerLab analog outputs.

    Stimulation Modes

    You can select the type of stimulus waveform generated in the Mode pop-up menu. The types of output waveforms can be selected in continuous or discrete waveform mode.

    The type of waveforms available may differ according to the hardware and software you are using.

    Stimulator modes dialog Stimulator Dialog allows stimulation parameters to be changed

    Easy Access Stimulator Panel

    Once the stimulation parameters are set up in the Stimulator dialog, you can easily start or stop stimulation, and change the settings while sampling using the Stimulator Panel mini-window.

    The Stimulator Panel mini-window floats in front of the active LabChart View window and can be moved around the screen. It gives you quick and easy control of stimulation parameters, including frequency, duration and amplitude.

    Stimulator Panels Stimulator Panel

    Feature Manager

    You can browse and obtain any of ADInstruments software from one interface. Features include:

    • Product panel: The entire catalogue of LabChart software is listed. Choose your product and click the “Get” button to automatically download and install the software.
    • Category panel: LabChart software is grouped into general and scientific application categories.
    • Information panel: Describes the major features and functions of the selected product.
    • Schedule/Check for Updates: checks for the latest software updates, either manually or automatically at daily, weekly or monthly intervals.
    • Register: Registered PowerLab users have free access to ADInstruments software updates, LabChart Extensions, teaching experiments, application notes and other special offers.
    • Search: Feature Manager will find suitable LabChart software based on keywords typed in the Search box.
    Feature Manager Dialog Browse and obtain ADInstruments software from the Feature Manager Dialog

    Download Tip  Download: Feature Manager Software Tip(222 KB)


    For more information, or an obligation-free demonstration of the PowerLab data acquisition system including LabChart software, contact your local ADInstruments representative.