Thank you for your interest in 4 Channel Extracellular Differential Amplifiers. Please complete and submit the form below and an ADInstruments representative will aim to get in touch within one working day. If you’d like to speak to someone immediately, office contact information is available from the contact page.
×Thank you for your interest in 4 Channel Extracellular Differential Amplifiers. Please complete and submit the form below and an ADInstruments representative will aim to get in touch within one working day. If you’d like to speak to someone immediately, office contact information is available from the contact page.
×Thank you for your interest in 4 Channel Extracellular Differential Amplifiers. Please complete and submit the form below and an ADInstruments representative will aim to get in touch within one working day. If you’d like to speak to someone immediately, office contact information is available from the contact page.
×DP-304A/IC-4M
A low noise, high input impedance, four channel AC/DC differential amplifier ideally suited for animal ECG/EKG, EEG and extracellular recordings. It has a voltage gain of x10, x100, x1000 and x10,000 and a CMR of 120 dB min at 60 Hz. Four IC-4M Input Cable Set for DP-301/304 (2mm Pin/Alligator Clip, 2pk) are supplied.
DP-304A/IC-2S
A low noise, high input impedance, four channel AC/DC differential amplifier ideally suited for animal ECG/EKG, EEG and extracellular recordings. It has a voltage gain of x10, x100, x1000 and x10,000 and a CMR of 120 dB min at 60 Hz. Four standard IC-2S Input Cable Set for DP-301/304A (Unterminated, 2 pk) are supplied.
DP-314
A low noise, high input impedance, four channel AC/DC differential amplifier that is designed to function with active headstages, which together are ideally suited for extracellular recordings. It has a voltage gain of x10, x100, x1000 and x10,000 and a CMR of 120 dB min at 60 Hz. Four active headstages are supplied, which are compatible with E Series Electrode Holders (purchased separately).
PRICE ON REQUEST
A four channel low noise, high input impedance, AC/DC differential amplifier, which ideally suited for animal ECG/EKG, EEG and extracellular recordings.
A four channel AC/DC pre-amplifier designed for recording animal ECG/EKG, EEG and even weaker extracellular action potentials. Its features include:
Amplified signals can be recorded and analysed using a PowerLab and LabChart data acquisition system.
https://www.adinstruments.com/products/4-channel-extracellular-differential-amplifiers#product-DP-304A/IC-4M
DP-304A/IC-4M
A low noise, high input impedance, four channel AC/DC differential amplifier ideally suited for animal ECG/EKG, EEG and extracellular recordings. It has a voltage gain of x10, x100, x1000 and x10,000 and a CMR of 120 dB min at 60 Hz. Four IC-4M Input Cable Set for DP-301/304 (2mm Pin/Alligator Clip, 2pk) are supplied.
https://www.adinstruments.com/products/4-channel-extracellular-differential-amplifiers#product-DP-304A/IC-2S
DP-304A/IC-2S
A low noise, high input impedance, four channel AC/DC differential amplifier ideally suited for animal ECG/EKG, EEG and extracellular recordings. It has a voltage gain of x10, x100, x1000 and x10,000 and a CMR of 120 dB min at 60 Hz. Four standard IC-2S Input Cable Set for DP-301/304A (Unterminated, 2 pk) are supplied.
https://www.adinstruments.com/products/4-channel-extracellular-differential-amplifiers#product-DP-314
DP-314
A low noise, high input impedance, four channel AC/DC differential amplifier that is designed to function with active headstages, which together are ideally suited for extracellular recordings. It has a voltage gain of x10, x100, x1000 and x10,000 and a CMR of 120 dB min at 60 Hz. Four active headstages are supplied, which are compatible with E Series Electrode Holders (purchased separately).
Our Support Articles contain answers to common questions, how-tos, solutions, and documentation.
Maximize time and resources with our customized training services delivered at your facility, on your equipment, on your terms.
See Training & WorkshopsOrdering information:
Summary:
DP-304A | DP-314 | |
---|---|---|
Voltage Gain, AC/DC | x10, x100, x1,000 and x10,000 | |
Input Resistance, Z (typical) | 1012 Ω | |
Leakage Current (typical) | 1.0 pA typical | |
Common Mode Rejection, CMR | 120 dB min (1,000,000:1) at 60 Hz | |
Noise, input shorted | 8 µV p-p, 1 Hz to 10 kHz | |
Low Frequency Filter Settings (high pass) | 0.1, 1.0, 10 and 300 Hz | DC, 0.1, 1, 10, 100 and 300 Hz |
High Frequency Filter Settings (low pass) | 0.1, 0.3, 1.0, 3.0, 10 and 50 kHz | 0.1, 0.5, 1, 5, 10 and 50 kHz |
Offset Control Range | ±600 mV min at output, any gain setting | |
Calibration Signal | 1 mV p-p at 10 Hz | |
Max. Common Mode Signal | ±2 V | ±10 V |
Output Voltage Swing | ±10 V, ±5 V at x10 gain | ±10 V |
Output Resistance | 50 Ω | |
Input and Output Connectors | BNC | |
Power Requirements | 92 - 250 VAC, 50/60 Hz, 20 VA | |
Physical Size (H x W x D) | 9.0 x 42.5 x 19.0 cm | |
Shipping Weight | 4.55 kg | 5.5 kg |
Warranty | One year on electrical components |
Operating System | Recommended Hardware | Alternate Hardware | |
LabChart Lightning | Mac/Windows | PowerLab C + Instrument Interface | Traditional PowerLab |
LabChart 8 | Mac/Windows | PowerLab C + Instrument Interface | Traditional PowerLab |