Get a quote

Thank you for your interest in Small Animal Telemetry Implants. Please complete and submit the form below and an ADInstruments representative will aim to get in touch within one working day. If you’d like to speak to someone immediately, office contact information is available from the contact page.

×

Ask a question

Thank you for your interest in Small Animal Telemetry Implants. Please complete and submit the form below and an ADInstruments representative will aim to get in touch within one working day. If you’d like to speak to someone immediately, office contact information is available from the contact page.

×

Request a demo

Thank you for your interest in Small Animal Telemetry Implants. Please complete and submit the form below and an ADInstruments representative will aim to get in touch within one working day. If you’d like to speak to someone immediately, office contact information is available from the contact page.

×
×
checkmark Item successfully added to your quote request.

Small Animal Telemetry Implants

DSI201O-P, DSI202O-P, DSI203O-P, DSI20601-P, DSI20801-P, DSI20401-P, DSI10502-ACA

Configurations


HD-S10 Small Implant

DSI201O-P

Collects pressure, activity, and temperature, e.g. rat blood pressure. Reduced weight from preceding model for improved animal welfare and up to 5 months of battery life. Multiple length options available.


HD-S11 Small Implant

DSI202O-P

Ability to collect pressure, biopotential, activity, and temperature. Ideal for cardiovascular studies and a variety of catheter lengths to accommodate a diverse range of research needs. Multiple length options available. Option to include a secondary implant (sold separately) for use in paired housing scenarios or for recording from two implants in an individual animal. In these scenarios, an RPC-3 PhysioTelTM Receiver will be required.


HD-S21 Small Implant

DSI203O-P

Collect two pressure signals plus biopotential, activity, and temperature for a wide range of applications and configurations. Ideal for high-fidelity applications recording pulse wave velocity or a combination of pressure signals like left ventricle with systemic blood pressure. Multiple length options available.


HD-S02 Small Implant

DSI211O-P

Continuously collects 2 biopotential channels, activity and temperature. Most commonly used for neurophysiology and electrophysiology studies in mice. Wider bandwidth in low frequencies (< 1 Hz) helpful for scoring slow wave sleep whereas in high frequencies (> 50 Hz) this is helpful across multiple neuroscience applications.


4ET Small Implant

DSI204O-P

The is the most comprehensive small animal implant for CNS studies, this option records temperature, activity and up to four EEG channels. Option to include a secondary implant (sold separately) for use in paired housing scenarios or for recording from two implants in an individual animal. In these scenarios, an RPC-2 PhysioTelTM Receiver will be required. 


F40-TT Small Implant

DSI20801-P

This dual thermistor tipped temperature probe records two temperature channels and one activity channel, example use in fat tissue studies. Battery life up to four months.


F50-W-F2

DSI10502-ACA

The F50-W-F2 (DSI10502-ACA or -IND) is a PhysioTel implant designed to wirelessly acquire sympathetic nerve activity (SNA) from rats and similarly sized species. The implant measures one high bandwidth biopotential signal.  The F50-W-F2 transmits data using a different frequency (18MHz known as frequency 2 or ‘F2’) than most PhysioTel implants, therefore, it may be implanted with another implant of a different frequency (F0 or F1) in the same subject allowing the simultaneous measurement of SNA with other data types such as blood pressure. This enables tremendous flexibility in designing your autonomic nervous system studies. The F50-W-F2 implant can be re-sterilized and re-implanted in multiple subjects.


×

Small Animal Telemetry Implants

PRICE ON REQUEST

PhysioTelTM HD Implants from DSI are the most advanced small animal telemetry products available on the market today.

Book a Demo

Overview

Unsurpassed in the field of telemetry the PhysioTelTM HD Implants from DSI are the most advanced small animal telemetry products available on the market today. Easy to use with enhanced performance and proven success, implants are designed for subcutaneous or intraperitoneal placement in small animal models such including rat, guinea pig or rabbit.  Both PhysioTelTM HD and other PhysioTelTM small animal telemetry implant sensors can record a varying range of signals including:

All implants provide improved animal welfare by allowing the subject to move freely within the cage. The electronics enclosure are hermetically sealed to ensure successful use in extended duration studies.

Additional benefits of PhysioTelTM HD Implants:

  • Ease of use and time saving afforded through implant autoconfiguration
  • Encoded animal ID to prevent incorrect data collection
  • Battery life monitoring capabilities.

Additional hardware and software is required to complete recording and analysis. The Biopotential Telemetry Foundation System or Pressure Telemetry Foundation System combined with your choice of implants are the perfect base to build a comprehensive solution tailored for your research.

DSI Exchange Program
PhysioTelTM implants can be sterilized between uses to extend their life. To further reduce costs you can exchange your used PhysioTelTM implants for replacement implants at a fraction of the original price, while receiving the assurance that each replacement implants is guaranteed for performance and quality. Find out more 

Recommended Accessories:

Learn more about Mouse and Small Animal Telemetry for ADInstruments and DSI 

Note: A comprehensive range of implants is available, please contact us for a full list 

 

Configurations


HD-S10 Small Implant

DSI201O-P

Collects pressure, activity, and temperature, e.g. rat blood pressure. Reduced weight from preceding model for improved animal welfare and up to 5 months of battery life. Multiple length options available.

HD-S11 Small Implant

DSI202O-P

Ability to collect pressure, biopotential, activity, and temperature. Ideal for cardiovascular studies and a variety of catheter lengths to accommodate a diverse range of research needs. Multiple length options available. Option to include a secondary implant (sold separately) for use in paired housing scenarios or for recording from two implants in an individual animal. In these scenarios, an RPC-3 PhysioTelTM Receiver will be required.

HD-S21 Small Implant

DSI203O-P

Collect two pressure signals plus biopotential, activity, and temperature for a wide range of applications and configurations. Ideal for high-fidelity applications recording pulse wave velocity or a combination of pressure signals like left ventricle with systemic blood pressure. Multiple length options available.

HD-S02 Small Implant

DSI211O-P

Continuously collects 2 biopotential channels, activity and temperature. Most commonly used for neurophysiology and electrophysiology studies in mice. Wider bandwidth in low frequencies (< 1 Hz) helpful for scoring slow wave sleep whereas in high frequencies (> 50 Hz) this is helpful across multiple neuroscience applications.

4ET Small Implant

DSI204O-P

The is the most comprehensive small animal implant for CNS studies, this option records temperature, activity and up to four EEG channels. Option to include a secondary implant (sold separately) for use in paired housing scenarios or for recording from two implants in an individual animal. In these scenarios, an RPC-2 PhysioTelTM Receiver will be required. 

F40-TT Small Implant

DSI20801-P

This dual thermistor tipped temperature probe records two temperature channels and one activity channel, example use in fat tissue studies. Battery life up to four months.

F50-W-F2

DSI10502-ACA

The F50-W-F2 (DSI10502-ACA or -IND) is a PhysioTel implant designed to wirelessly acquire sympathetic nerve activity (SNA) from rats and similarly sized species. The implant measures one high bandwidth biopotential signal.  The F50-W-F2 transmits data using a different frequency (18MHz known as frequency 2 or ‘F2’) than most PhysioTel implants, therefore, it may be implanted with another implant of a different frequency (F0 or F1) in the same subject allowing the simultaneous measurement of SNA with other data types such as blood pressure. This enables tremendous flexibility in designing your autonomic nervous system studies. The F50-W-F2 implant can be re-sterilized and re-implanted in multiple subjects.

×
checkmark Item successfully added to your quote request.
HD-S10 Small Implant

HD-S10 Small Implant

DSI201O-P

×
checkmark Item successfully added to your quote request.
HD-S11 Small Implant

HD-S11 Small Implant

DSI202O-P

×
checkmark Item successfully added to your quote request.
HD-S21 Small Implant

HD-S21 Small Implant

DSI203O-P

×
checkmark Item successfully added to your quote request.
HD-S02 Small Implant

HD-S02 Small Implant

DSI211O-P

×
checkmark Item successfully added to your quote request.
4ET Small Implant

4ET Small Implant

DSI204O-P

×
checkmark Item successfully added to your quote request.
F40-TT Small Implant

F40-TT Small Implant

DSI20801-P

×
checkmark Item successfully added to your quote request.
F50-W-F2

F50-W-F2

DSI10502-ACA

Support

Support Articles

Our Support Articles contain answers to common questions, how-tos, solutions, and documentation.

Training and Workshops

Maximize time and resources with our customized training services delivered at your facility, on your equipment, on your terms.

See Training & Workshops

Details and Tech Specs

Product Codes


DSI201O-P
HD-S10 Small Implant
DSI202O-P
HD-S11 Small Implant
DSI203O-P
HD-S21 Small Implant
DSI211O-P
HD-S02 Small Implant
DSI204O-P
4ET Small Implant
DSI20801-P
F40-TT Small Implant
DSI10502-ACA
F50-W-F2

Technical

  HD-S10 HD-S11 HD-S21 HD-S02 F40-TT 4ET

Auto Configuration

-

-

Encoded Animal ID

-

-

Battery Life Monitoring

-

-

Pressure Channels

1

1

2

-

-

-

Pressure measurement

-20 to 300 mmHg

-

-

-

Pressure Lead and Tip

80 mm with 6 mm tip*

2x 80 mm with 6 mm tip*

-

-

-

Biopotential Channels

-

1

1

2

-

4

Biopotential Measurement

-

+/-5 mV

+/-1.25 mV

-

(+/-2.5 mV)

Biopotential lead wires

-

2x 300 mm

4 x 200 mm with 0.3 mm outer diameter electrodes

-

8x 500 mm with 0.3 mm outer diameter electrodes*

Temperature

2**

Activity

Active Battery (months)

5

2

2

5

4

3***

Weight (g)

4.4

8

8

4.7

7.5

12.8

Volume (cc)

3.1

5.9

5.9

3.3

3.5

8.8

Frequency

455kHz

8 MHz

2nd implant for paired housing available

-

✓ (18 MHz frequency)

-

-

-

✓ (18 MHz frequency)

Ideal operating temp

34-41°C

Shelf life

1 year

9 months

Suture ribs

If intraperitoneal - yes, if subcutaneuous - no

-

Small Animal Sizing

>175 g

>200 g

Typical Cage Size

42 x 42 x 18 cm

Placement

Options for both intraperitoneal or subcutaneous placement

Subcutaneous

* Different length options available

** 2 x external thermistor-tipped probes (1.8mm diameter)

*** User replaceable

Ask a question×