Breadcrumb
- Home
- Search
image
Transonic
Partners
… flow solutions to the world Transonic Transonic Related Applications Tubing Flow Invasive Blood Flow Isolated Tissue and Organs Ventricular Pressure-Volume Support … Related Applications Tubing Flow → ADInstruments and Transonic for Tubing Flow Research Isolated Tissue and Organs → ADInstruments and Transonic for Isolated … and systemic organ blood flow in hemorrhagic shock using a rabbit model Nature Cardiovascular Research Singh et al. Robotic right ventricle is a biohybrid …
image
… of Porto Pedro Ferreira is a Biologist from Portugal, who obtained his PhD in Cardiovascular Sciences in 2017 at the Faculty of Medicine of the University of … Familial Migraine. He is also a Medical Doctor, qualified earlier this year. Invasive blood pressure measurements in rodents for nephrology-related research - Merle Maas-Krebber at UMCU Merle will finish her PhD on regenerative …
video
… experts who are using Transonic fluid flow measurements in their perivascular research. This event offers a valuable platform for researchers to connect, exchange … from four researchers who currently use Transonic Systems in their small and large animal studies Address frequent research challenges such as surgery and placement of … Hypertension Research (L3 Investigator NHMRC), Department of Physiology Head, Cardiovascular Disease Program, Biomedical Discovery Institute Monash University, …
image
… Complete data acquisition solutions for your research Accurate, reliable, powerful and easy to use – we provide you with the tools … More Accessories and Parts Consumables Applications and Signals Human Animal In Vitro Autonomic HRV Electrocardiography (ECG/EKG) Human Non-invasive Blood Pressure (NIBP) Microneurography Cardiovascular Human Invasive Blood Pressure Monitoring Non-Invasive Blood Pressure …
video
… In this webinar, Dr. Rohit Ramchandra from the University of Auckland discusses how cardiovascular disease remains one of the leading causes of death worldwide and how research studies in large animals are vital to translating findings from research … and renal blood flow in an ovine model of hypertension. Additional resources: Invasive Blood Pressure – fundamentals and best practices for preclinical research» …
video
… Kevin O’Gallagher, PhD, discuss planning for success when translating preclinical research and the importance of building relationships with their clinical colleagues. … control in spinal cord injury patients Telemetry for long-term monitoring of animal models of hypertension, ischemic stroke, and diabetes Invasive and noninvasive … Driven by his passion for the complex interactions between the nervous and cardiovascular systems, including anomalous interactions contributing to clinical …
image
… Kaha Small Animal Telemetry Systems Continuous, High-Quality Data from Freely Moving Animals. … acquisition and analysis of large data sets while enhancing animal welfare and research efficiency. Kaha telemeters provide reliable telemetry monitoring for cardiovascular, neurological, and autonomic rodent research. Ask a Question Resources …
… be measured in situ and why tissue oxygen telemetry could be beneficial to your research... Overview: 1. Why is tissue oxygen an important measure? 2. Techniques … imaging techniques offer a large field of view, they all require some level of animal restraint/anesthesia that can limit the types of studies performed. Newer … that be days, weeks, or months. Given that some forms of dementia, stroke and cardiovascular diseases are associated with alterations in blood flow, the ability to …
… PV Loops are the gold-standard method for assessing cardiac function in animal studies. The technique produces load-independent measurements of heart … and treatment models. It turns out, one of the greatest limits of pressure-volume research is the non-standardized approach to performing and publishing this research. … understanding of cardiac function. Anesthetics All anesthetics cause some level of cardiovascular disruption, so the choice must be made carefully based on the …
… What is isolated organ research - and why should you be doing it? As the name implies, isolated organ … of the experiment protocol as required by the study. In addition, since it is an invasive method, you can directly place sensors or electrodes on the organ … Helping with matters of the (isolated) heart: Simplicity & flexibility for cardiovascular and pharmacology research References Yeh T., Wechsler A.S. (1998) The …
… with high fidelity. Below we have outlined some unique intracranial pressure research applications using Mikro-Tip® catheters , plus some applications that … SPR-751S . This broad approach ensures simultaneous measurement of intracranial, cardiovascular, and intrapleural pressures for a complete overview of the impact of … of the Millar pressure catheter » Solid-state vs. Fluid-filled catheters | Invasive blood pressure telemetry» What are the physical dimension of the Mikro-Tip …
image
… C Series C Series FAQ Stay up to date Why use the PowerLab C? Future-proof your research by investing in a system that adapts to your needs. The PowerLab C and C … | Amplification, Filtering and Sampling For All Your Life Science Needs Human Animal In Vitro Autonomic HRV Electrocardiography (ECG/EKG) Human Non-invasive Blood Pressure (NIBP) Microneurography Cardiovascular Human Invasive Blood Pressure Monitoring Non-Invasive Blood Pressure …
… Millar pressure catheters are primarily designed for measuring highly accurate cardiovascular pressures , these sensors have been used for measuring a range of … IFP, and reduced treatment response. Mice are by far the most commonly used animal model in cancer research, leading to a range of well-established methods for direct and …
… the contractility of heart independent of preload and afterload. In this blog, Cardiovascular Physiologist Adam Goodwill (P.h.D) from Indiana University School of … By inserting a PV catheter into the left or right ventricle of an anesthetized animal, you can measure all load-dependent data for every cardiac cycle from the … interstitial fluid, airway, and spinal pressures Adam G. Goodwill, PhD Assistant Research Professor, Anatomy Cell Biology & Physiology Indiana University School of …
image
… techniques required to maximize PV Loop data accuracy and reproducibility in small-animal models. The workshop will be hosted by Dr. Chris West in his Translational … at the University of British Columbia Okanagan. Workshop Topics: Fundamental cardiovascular and hemodynamic principles History and current landscape of PV Loop … and translational physiology. With over 15 years of experience, Chris’s research has significantly advanced the field of cardiovascular physiology through …