LabChart Support

Beginners Guide to using LabChart

If you don't already have a license but want to try it out, request a demo licence

 

Licensing Information

LabChart 8 offers a range of data recording and analysis or analysis only licence options. Find out more.

 

Getting Started

Within the Welcome Centre of LabChart, you will be provided with a helpful getting started Tutorial with tips and tricks to help get you up and running quickly.

Get a quick overview now

Take it to the next level

  • Expand and deepen your knowledge of data acquisition and analysis with LabChart 8 through our online training course. Find out more

LabChart Videos

Filter videos

LabChart Version

GLP Software for LabChart

LabChart Add-Ons

info The easiest way to install Add-Ons is via LabChart's Feature Manager.

Services and training

Our range of interactive, hands-on courses and workshops reduce on-boarding time, and work to increase efficiency and output, helping you achieve your education and research aims, faster.

Online Training Course

Expand and deepen your knowledge of data acquisition and analysis with LabChart 8 through our online training course.

 

An ideal resource for those wishing to learn in their own time and pace, or looking for an option to train lab staff when social distancing is in place. This course is an online version of our 2-day in person training option via our own active learning educational platform, Lt. Course content includes:

  • Data acquisition basics
  • Filtering and smoothing
  • Using Chart, Scope and Spectrum Views
  • Advanced analysis features, such as Macros and Arithmetic
  • Training on each of the LabChart Pro advanced modules

A comprehensive and interactive way to unlock the meaning of your data.

Each lesson contains:

  • Learning objectives
  • Technique / feature overviews
  • Video-directed exercises with demo files
  • Interactive questions and answers

This option is currently available in North America, South America, UK, and the EU. If you are interested in further details or access to this course, please fill out the form below and we will be in touch.

Show releases for:

LabChart 8.1.17 (Mac)

Mac changes

  • Fixed an issue where a calculated channel unexpectedly stops producing data while sampling.
  • Fixed a pod setup issue such that the Grip Force transducer now produces correct data values during sampling.

New Known Issues

There are no new known issues in this release.

LabChart 8.1.16 (Mac)

Mac changes

  • Fixed issue where using the FE2XX Series Bio-amp (Octal, Quad, Dual and Neuro amps) input Low pass filters with cutoff frequencies of 1 kHz or lower could introduce inter-channel delays of up to ~1.5 ms.
  • Fixed issue where the FE2XX Series Bio-amp bandwidth was lower than expected at sampling rates below 100 kS/s. This also affected sampling with slave devices when sampling from multiple devices into the same document, e.g. when sampling with two PowerLabs the slave device would have a lower bandwidth than the master device.
  • Fixed issue with the delay compensation for FE2XX Bio-amp inputs. The delay between a signal recorded via the Bio-amp input relative to that recorded by a PowerLab input is now less than +/- 10 µs for sample rates above 100 S/s, and less than +/- 1 sample period for all sampling rates, so long as the PowerLab input and Bio-amp input have the same input low pass filter settings (including the case where the input low pass filters are both off).
  • New PowerLab Red enabler improves the self-calibration of 15 and 26 series PowerLabs (i.e. offset calibration on startup).
  • Fixed issue where making a selection in the Chart View could cause a bad access in the Zoom View.
  • Fixed an issue that prevented opening some files saved with LabChart 7 or earlier.
  • Fixed an issue where comment text is incorrect within certain files saved with LabChart 7 or earlier.
  • Fixed an issue where searching in the Help would return no results.

New Known Issues

There are no new known issues in this release.

LabChart 8.1.16 (Win)

Windows changes

  • Fixed issue where using the FE2XX Series Bio-amp (Octal, Quad, Dual and Neuro amps) input Low pass filters with cutoff frequencies of 1 kHz or lower could introduce inter-channel delays of up to ~1.5 ms.
  • Fixed issue where the FE2XX Series Bio-amp bandwidth was lower than expected at sampling rates below 100 kS/s. This also affected sampling with slave devices when sampling from multiple devices into the same document, e.g. when sampling with two PowerLabs the slave device would have a lower bandwidth than the master device.
  • Fixed issue with the delay compensation for FE2XX Bio-amp inputs. The delay between a signal recorded via the Bio-amp input relative to that recorded by a PowerLab input is now less than +/- 10 µs for sample rates above 100 S/s, and less than +/- 1 sample period for all sampling rates, so long as the PowerLab input and Bio-amp input have the same input low pass filter settings (including the case where the input low pass filters are both off).
  • New PowerLab Red enabler improves the self-calibration of 15 and 26 series PowerLabs (i.e. offset calibration on startup).

New Known Issues

There are no new known issues in this release

LabChart 8.1.15 (Mac)

Mac changes

  • Fixed issue introduced in LabChart 8.1.14 where exporting data as either MATLAB, IGOR or ADIBIN generates invalid output files.
  • Fixed stability issue introduced in LabChart 8.1.14 affecting certain files that contain either Digital Filter calculations or Arithmetic calculations making use of the + / - * operators.

New Known Issues

There are no new known issues in this release.

LabChart 8.1.14 (Mac)

Mac changes

  • Essential release adding support for macOS 10.15 Catalina and later.
  • The option to display data in the Chart View in “Sweep mode” has been removed from Display Settings. This change was made to prevent users experiencing responsiveness and stability issues when using the Chart View on machines having high resolution Retina displays.

Known Issues

  • For machines that have high-resolution Retina displays, users may encounter responsiveness and stability issues when using the Scope View.

LabChart 8.1.13 (Win)

  • Fix for a input amplifier related setting specific to the FE185 Neuro Amp EX
  • Added support for the upcoming Equivital Device Enabler 1.1 Multiple SEM file import feature release
  • Fixed sampling issue for LCC Hardware Options, specifically for the INL191 Blood FlowMeter
  • Updated Bioamp Application Firmware for FE285, FE231, FE232, FE234, and FE238

 

LabChart 8.1.13 (Mac)

  • Fix for a input amplifier related setting specific to the FE185 Neuro Amp EX
  • Fixed sampling issue for LCC Hardware Options, specifically for the INL191 Blood FlowMeter
  • Updated Bioamp Application Firmware for FE285, FE231, FE232, FE234, and FE238

LabChart 8.1.12 (Mac)

Mac and Windows

Copying and pasting text into external applications has been optimized for data accuracy.

LabChart Online features (Send and Publish) have been removed. There is no alternative within LabChart to replace these features.

Upcoming Bio Amps - support features:

  • LabChart 8.1.12 adds support for our upcoming Bio Amp variants: Single, Dual, and Neuro.
  • LabChart 8.1.12 contains firmware upgrades for current generation Octal and Quad Bio Amp units.
  • LabChart 8.1.12 enables 26 Series PowerLab compatibility with Single, Neuro, Dual, and Quad variants of the current generation of Bio Amps.
  • Enhanced the BP Amp calibration units conversion feature.
  • Improved accuracy of application of certain Bio Amp filter combinations.
  • Resolved communications issue that may have affected current generation Bio Amps.

Known Issues

Existing Quad and Octal Bioamps will require their PowerLab to be power-cycled after firmware upgrades, before LabChart will detect the connected channels correctly.

LabChart 8.1.12 (Win)

Mac and Windows

Copying and pasting text into external applications has been optimized for data accuracy.

LabChart Online features (Send and Publish) have been removed. There is no alternative within LabChart to replace these features.

Upcoming Bio Amps - support features:

  • LabChart 8.1.12 adds support for our upcoming Bio Amp variants: Single, Dual, and Neuro.
  • LabChart 8.1.12 contains firmware upgrades for current generation Octal and Quad Bio Amp units.
  • LabChart 8.1.12 enables 26 Series PowerLab compatibility with Single, Neuro, Dual, and Quad variants of the current generation of Bio Amps.
  • Enhanced the BP Amp calibration units conversion feature.
  • Improved accuracy of application of certain Bio Amp filter combinations.
  • Resolved communications issue that may have affected current generation Bio Amps.

Windows

Macros can now be saved in a Macro Library. This is a user-defined folder that allows any LabChart file opened on that computer to access them.

Known Issues

Existing Quad and Octal Bioamps will require their PowerLab to be power-cycled after firmware upgrades, before LabChart will detect the connected channels correctly.

 

LabChart 8.1.11 (Mac)

  • Exporting or copying and pasting text now produces correct data for channels containing Cyclic Measurements calculation data in multi-rate files.
  • Fixed an issue where LabChart might unexpectedly close after adjusting a channel height in certain files.