Large Animal PV Catheters
Product
Millar Ventri-Cath PV Loop catheters are designed for complete cardiac function assessment in continuously beating, intact hearts of large animals (including dog, pig and sheep).
Rat PV Catheters
Product
Millar Mikro-Tip® rat PV catheters These ultra-miniature Polyimide Nylon catheters can measure both ventricular pressure and volume simultaneously and continuously from the intact beating hearts of rats.
Mouse PV Catheters
Product
Millar offers the world's only solid-state Pressure-Volume (PV) catheters for cardiovascular research in mice.
Pressure Catheters
Product
Millar Mikro-Tip® solid state catheters with pressure sensor(s) provide high-fidelity cardiovascular pressures (the heart and vascular system) at the source in small animals. These catheters are ideal for intrauterine, intracranial and arterial blood...
Tissue Grinders
Product
Radnoti tissue grinders are constructed out of borosilicate glass and are designed for dependable performance, efficiency and durability.
Radnoti Tissue Ring Supports
Product
Radnoti Tissue Ring Supports that are designed specifically for mounting tissue ring samples such as aortic, intestinal, vascular or tissue ring segments that need to be set up for an isometric contractile force measurement. The design consists of a...
Borosilicate glass cannulas that are designed for easy insertion into the lid of the Radnoti High Tech Heart Chambers.
image
Left Ventricular Pressure
3D Model
To measure left ventricular pressure, the pressure catheter is inserted into the left ventricle and secured in place with a ring of sutures. Kaha Rat Pressure Telemeters use Millar Solid State pressure sensors. Unlike gel-filled catheters, solid...
image
EEG
3D Model
The Rat Biopotential Telemeter measures the biopotential difference between the two electrode leads. To record rat EEG, the two leads from the Rat Biopotential Telemeter must be tunneled up to the parietal bones of the skull and anchored in place...
image
Simultaneous EMG and EEG
3D Model
This model shows simultaneous EMG and EEG recording. The Rat Dual Biopotential Telemeter measures the biopotential difference within each pair of electrode leads, so care must be taken to ensure each lead is with its corresponding pair. One pair has...
image
SNA and Arterial Blood Pressure
3D Model
This model shows a Rat Pressure and SNA Telemeter simultaneously recording arterial blood pressure from the abdominal aorta, and sympathetic nerve activity from the renal nerve. All Kaha rat pressure telemeters use Millar solid-state pressure sensors...
image
Arterial Blood Pressure
3D Model
To measure arterial blood pressure, the Kaha Rat Pressure Telemeter body is implanted into the abdomen and the catheter sensor is inserted into the abdominal aorta. Kaha pressure telemeters are fitted with Millar solid-state pressure sensors...
image
Intracranial Pressure
3D Model
The model shows intracranial pressure being measured by the Rat Pressure Telemeter in the subdural space of the rat skull. The rat pressure telemeter is available in 9cm, 15cm, and 25cm lengths. The 25cm length is required for intracranial pressure...
image
ECG
3D Model
In this model a Rat Biopotential Telemeter is being used to record an invasive electrocardiogram. The two biopotential leads are located close to the heart and embedded in the muscle along the electrical axis of the heart. One lead is fixed to the...