ECG Analysis

ECG / EKG Analysis Software

Product Code MLS360/8

The ECG (EKG) Analysis Module for LabChart automatically detects and reports PQRST onset, amplitude and intervals in real time, or after recording.

Download Software

Frequently purchased with ECG Analysis

Overview

Using the ECG Analysis, HRV and Cardiac Axis tools

LabChart’s ECG Analysis Module provides you with an accurate and powerful way to interpret ECG waveform morphology in order to support a wide range of cardiovascular research areas such as:

  • Arrhythmia studies
  • Cardiovascular disease and myocardial dysfunction
  • Pharmacological impact on heart health
  • Heart rate variability (HRV)
  • Cardiomyopathy
  • Hypertension
  • Exercise and metabolic studies
  • Obesity
  • Animal performance and stress
  • Isolated hearts

The analysis software automatically detects and reports on P, Q, R, S, and T wave onsets, amplitudes, and intervals in real-time, or post data recording - allowing you to easily interpret and identify abnormalities in your ECG recordings.

Our software supports measurements from implantable telemetry devices as well as surface and intracardiac electrodes - combined with our Bio Amplifiers to ensure a clean ECG signal. Recordings can be analyzed with our pre-existing detection settings covering a variety of different animal models including:

  • Human
  • Pig
  • Dog
  • Rabbit
  • Guinea pig
  • Rat
  • Mouse

Furthermore, the raw data is unaltered by calculations, ensuring that the electrocardiogram can be reanalyzed. The ECG Analysis Module is suitable for a PC running Windows and is included as part of LabChart Pro or can be purchased separately. The Chart, Beat Classification, Table and Averaging Views are linked for swift and uncomplicated navigation to data points of interest, with easily perceptible manual/user data edits marked in red.

Get the most out of your cardiovascular data by combining the ECG Analysis Module with some additional LabChart Modules such as:

Cardiac Axis -  a heart axis calculator add-on for LabChart that automates calculation of frontal plane electrocardiograms and animates cardiac vector display.

HRV - the R-wave threshold detector identifies and calculates ECG beat-to-beat interval variation to automatically categorize beats as normal, ectopic, or artifact (can also be used with arterial pulse signal).

PV Loop - specifically designed for the analysis of in vivo ventricular pressure-volume data in small and large animals, or ex vivo, using working heart systems.

Peak Analysis - provides automatic detection and analysis of multiple, non-overlapping signal peaks.

A Powerful Platform for ECG Analysis

Our ECG/EKG Analysis Module for LabChart permits easy and rapid evaluation of cardiovascular activity and dysfunction. The module enables the identification ECG waveforms and automatically detects heart rhythm, amplitude, and P-, Q-, R-, S- and T-wave onset. Isolate the artial rate and ventricular rhythym with automated amalysis of P-waves and R-waves increasing the applications of your analysis.

The R-wave threshold detector identifies beat-to-beat intervals and automatically calculates HRV - an emergent measure of health and readiness. Identification of tachycardia and bradycardia is made easy with automated heart rate calculation. The analysis software also allows for the rapid quantification and export of a variety of conduction measures, including:

  • RR Interval
  • PR Interval
  • QT Interval
  • QRS Interval
  • QTc
  • T Amplitude
  • P Amplitude
  • R Amplitude

The Cardiac Axis Add-On is a powerful package that automates the calculation of frontal plane ECGs. Directional calculations of depolarization, repolarization and deflection allow for fast identification of left axis deviation and right axis deviation, powering your downstream analysis.

The ECG Module can also be used as a cardiology platform for ECG interpretation to assist in the detection of a variety of cardiovascular dysfunctions including arrhythmias, atrial fibrillation, atrial flutter, ischemia, left ventricular hypertrophy, right ventricular hypertrophy, and myocardial infarction. Perform interval analysis to facilitate the diagnosis of severe pathologies. Identify first-degree heart block (AV block) via the detection of prolonged P-R Interval or, second-degree heart block through the detection of intermittently dropped QRS complexes.

Lab Builder – Find the right products for your research.

1Select your research area

2Use our smart guide to tell us your needs

3Get instant product recommendations

    Try Lab Builder

    Related

    Research Applications

    Wireless Physiological Monitoring
    Human Exercise Physiology
    Wired Physiological Monitoring
    Human Exercise Physiology
    Biopotentials and GSR
    Human Psychophysiology
    Electrocardiography (ECG/EKG)
    Human Cardiovascular
    Langendorff
    Cardiovascular Isolated Heart Systems
    In Vitro Pharmacology + Isolated Tissue and Organs
    Working Heart
    Cardiovascular Isolated Heart Systems
    In Vitro Pharmacology + Isolated Tissue and Organs
    Biopotentials
    Human Sleep Studies
    Electrocardiography (ECG/EKG)
    Human Autonomic
    Small Animal Telemetry
    Animal Telemetry
    Isolated Organ
    In Vitro Pharmacology + Isolated Tissue and Organs
    Surface ECG
    Cardiovascular Cardio Electrophysiology
    ECG
    Animal Autonomic
    HRV
    Animal Autonomic
    Biopotentials
    Animal Telemetry

    Signals

    Key Features

    ECG Settings

    • Analysis of real-time or saved ECG traces
    • Analysis of ECG data from any species, including tailored algorithms for human, rat and mouse ECG analysis.
    • Customizable settings for optimal identification of ECG waveforms.
    • Automatic detection and averaging of ECG cycles with the option to average a specified number of beats, or all the beats across a specified time period or in a block.

    ECG Beat Classification

    • ECG Beat Classifier identifies ectopic beats and other cardiac arrhythmias by identifying noise-contaminated waveforms and waveforms with abnormal QRS shapes or RR intervals.
    • The first beat marker is always displayed in gray. Beat markers included in analysis are green. Red marker color indicates exclusion from analysis based on signal noise. Blue color indicates exclusion due to form factor, and pink signifies exclusion due to noise as well as form.

    ECG Beat Averaging View

    • ECG Beat Averaging View is useful in reducing the effects of noise or movement artifacts and to compare the effects on the ECG before and after experimental intervention.
    • Provides automatic logging and displaying of selected ECG parameters of start, end, amplitude and PQRST interval times in tabular and graphical format.

    ECG Table View

    ECG Table View calculates and records the parameters of each averaged ECG beat that can easily be added to the Data Pad or exported to other graphing or statistical programs. Available parameters include:

    • P, Q, R, S, T amplitudes
    • Time intervals such as RR, PR, JT,QT and QTc

    Analysis Plots

    Automatic generation of Analysis Plots from calculated parameters:

    • QT/RR Plot (QT Interval versus RR Interval)
    • QT/Time Plot (ideal for pharmacokinetics)
    • RR/Time Plot (indicates HR variance)
    • Waterfall Plot (3D waveform analysis)

    Details and Tech Specs

    Technical

    Compatibility

    LabChart 8 for Windowscheckmark
    LabChart 8 for Mac-

    Product Code

    MLS360/8
    ECG Analysis

    Brochures

    Expand your research with solutions from our partners