Rat Telemeters

Kaha Sciences rat telemeters provide the ideal solution for research scientists looking to record high quality wireless telemetry signals.

Frequently purchased with Rat Telemeters

Overview

Features of Kaha Rat Telemeters

  • Powered by the SmartPad using patented wireless inductive technology, providing higher sampling rates (2 kHz) and temporal resolution for superior data quality.
  • Supports unique signal acquisition including tissue oxygen and SNA.
  • Pressure sensors incorporate Millar Mikro-TipTM catheter technology for unparalleled signal quality in a telemetry system.
  • Data transmission range up to 5 meters with battery backup and in vivo recharging allows for experimental scenarios where a greater range of movement is required e.g. water maze behavioural studies.
  • Cohousing feature enables two rats in the same cage or single rat (>350g) implanted with two telemeters.
  • All implants provide improved animal welfare by allowing the subject to move freely within the cage, a cohousing option to reduce stress of single housing, and being fully software controlled to reduce handling/impact of stress. Find out more about the benefits of telemetry.
  • Simple and customizable system setup: build a flexible telemetry system tailored to your research needs.

Options available to measure and transmit high-fidelity physiological signals such as:

Pressure

Biopotentials
(ie., ECG, EMG, EEG)

Sympathetic nerve
activity (SNA)

Tissue oxygen

Temperature (output
in all telemeters)

Configure a system to meet your exact needs

Telemeter of your choice

+

One SmartPad
per animal

+

One Configurator
System per lab

+

 

 

Simple and Customizable Telemetry System Setup

Configure a Kaha Sciences Rat telemetry system to meet your exact research needs. A typical telemetry setup requires one telemeter of your choice and one SmartPad per animal. Each laboratory will just require one Configurator in order to configure all your Kaha equipment.

  1. Select and pair transmission frequencies between SmartPads and their Telemeters using Configurator.
  2. Surgically implant the Telemeter.
  3. Connect the SmartPad to a PowerLab and/or Instrument Interface via BNC.

You are then ready to analyze your data using LabChart 8 or LabChart Lightning.

Cohousing

An additional advantage of a Kaha Sciences Rat Telemetry System is the cohousing feature:

  • Allows two rats (>175g), each implanted with one telemeter, to be housed together in a single cage to reduce stress of single housing and lab space requirements, or
  • Two telemeters to be implanted in one animal (>350g), allowing the measurement of up to four physiological signals (e.g. Oxygen + dual pressure or oxygen + SNA with pressure)

With Cohousing, the system continues to regulate the power supplied to both telemeters seamlessly while collecting continuous data with the expected accuracy and quality. Cohousing still requires one SmartPad per telemeter, as well as a Configurator System for the laboratory.

Existing systems can be upgraded to use the Cohousing feature without the need to purchase additional hardware. Cohousing also requires ConfigSoft software version 3.0 or later.

 

Find out more about Small Animal Telemetry with ADI and Kaha Sciences

Product Configurations

Biopotential Telemeter (ECG, EEG, EMG)

Product Code
TR50B

The Rat Biopotential Telemeter measures the biopotential difference between the two electrode leads. These leads can be placed to measure a single biopotential signal such as ECG, EEG, or EMG. Weighs ~12 g (7 cm3) and includes 25 cm long biopotential leads.

Placement in a rat model

Dual Biopotential Telemeter (ECG, EEG and/or EMG)

Product Code
TR50BB

The Dual Rat Biopotential Telemeter measures the biopotential difference between each pair of electrode leads. The leads can be used to measure two biopotential signals such as ECG, EMG and/or EEG. Weighs ~12 g (7 cm3) and includes 25 cm long biopotential leads.

Placement in a rat model

Pressure Telemeter

Product Code
TRM54P

The Rat Pressure Telemeter measures high fidelity pressure using a solid-state Millar Mikro-TipTM sensor. Pressure is measured directly at the tip of the catheter (2Fr in diameter, 9 cm long (15 cm & 25 cm options available)) and the telemeter can be used to measure arterial, venous, ventricular or intracranial pressure (25 cm catheter required). The telemeter weighs approximately 12g.

Pressure Biopotential Telemeter

Product Code
TRM54PB

The Rat Pressure Biopotential Telemeter combines measurement of high-fidelity pressure using a solid-state Millar Mikro-TipTM sensor with a single biopotential signal (e.g. ECG, EEG or EMG). Pressure is measured directly at the tip of the pressure catheter (2Fr in diameter, 9 cm long (15 cm & 25 cm options available)) and the telemeter can be used to measure arterial, venous, ventricular or intracranial pressure (25 cm catheter required). The biopotential signal measures the potential difference between the pair of 25 cm coiled electrode leads. The telemeter weighs approximately 12g.

Dual Pressure Telemeter

Product Code
TRM54PP

The Rat Dual Pressure Telemeter measures two high-fidelity pressures using solid-state Millar Mikro-TipTM sensors. Pressure is measured directly at the tip of each pressure catheter (2Fr in diameter, 9 cm long (15 cm & 25 cm options available)) and the telemeter can be used to measure arterial, venous, ventricular and/or intracranial pressures (25 cm catheter option).

SNA and Pressure Telemeter

Product Code
TRM56SP

The Rat Sympathetic Nerve Activity (SNA) and Pressure Telemeter is the only commercially available telemetry device that allows concurrent measurement of SNA and pressure. the telemeter weighs approximately 12 g with a Millar solid state pressure sensor (2Fr in diameter, 9 cm long (15 cm & 25 cm options available)) and multi-stranded SNA lead wires (25 cm long). The telemeter samples the pressure and SNA signals at 2 kHz with an SNA input range of ±60 µV.

Placement in a rat model

Tissue Oxygen Telemeter

Product Code
TR57Y

The Rat Tissue Oxygen Telemeter is an implantable potentiostat with a carbon paste electrode specifically configured for measuring tissue (e.g. brain, kidney) oxygen concentration in freely moving rats >175 g. The telemeter can be easily cleaned and sterilized for reuse after attachment of new electrodes. Ideal option for cohousing option in order to measure tissue oxygen measurement with other signals by placing two telemeters in one rat.

Lab Builder – Find the right products for your research.

1Select your research area

2Use our smart guide to tell us your needs

3Get instant product recommendations

    Try Lab Builder

    Related

    Research Applications

    Small Animal Telemetry
    Animal Telemetry
    Evoked Responses and Stimulation
    Animal Neuroscience
    Nerve Recording
    Animal Autonomic
    Blood Pressure
    Animal Autonomic
    ECG
    Animal Autonomic
    HRV
    Animal Autonomic
    Tissue Oxygen
    Animal Tissue and Circulation

    Key Features

    • Encased in durable, biocompatible hard-shell (liquid crystal polymer)
    • Suitable for use in rats >175g
    • High frequency sampling transmission (2kHz)
    • All telemeter options measure temperature as a recorded signal (except in cohousing mode)
    • When used on the SmartPad, supports continuous recording for extended sampling periods
    • Battery backup allows the telemeter to continue transmitting data for up to 4-6 hours (telemeter model dependent) if the animal is away from the SmartPad recharging field (up to 5 meters distance).
    • Reliable data recording capabilities with no data loss, crossovers or interference - 40 independent data collection frequencies to choose from using Configurator System

    Support

    Support Articles

    Our Support Articles contain answers to common questions, how-tos, solutions, and documentation.

    Training and Workshops

    Maximize time and resources with our customized training services delivered at your facility, on your equipment, on your terms.

    See Training & Workshops

    Details and Tech Specs

    Technical

    General Telemeter Specifications

    Temperature operating range8 to 41 degrees Celsius
    Sampling frequency2 kHz
    Low Pass filter cut-off frequency (SmartPad)1 kHz
    Transmission rangeUp to 5 m (may depend on laboratory environment)
    Transmitted signal2.4 GHz, fully digital
    Transmission frequencies40 available, configured by user
    Minimum rat weight175 g
    Outer materialBiocompatible hard-shell (liquid crystal polymer)
    Weight~13.5g
    Dimensions31.5 x 24 x 11 mm
    Battery lifeContinuous charging on SmartPad. Out of SmartPad charging field, battery life is ~4.6 hrs.
    Recharge time3 hours minimum
    Power On-offActivation by SmartPad & deactivation by Configurator System.
    Analog output calibration valuePressure: 1V output = 0mmHg, 2V output = 100 mmHg
    Biopotential: 2V output = 0mV input, 4V output = 2 mV input
    SNA: 2V output = 0µV input, 4V output = 60 µV input
    Temperature: 0V output = 0℃, 1V output = 20℃

    Individual Model Specifications

     TR50B
    Biopotential Telemeter
    TR50BB
    Dual Biopotential Telemeter
    TRM54P
    Pressure Telemeter
    TRM54PB
    Pressure Biopotential Telemeter
    TRM54PP
    Dual Pressure Telemeter
    TRM56SP
    SNA & Pressure Telemeter
    TR57Y
    Tissue Oxygen Telemeter
    Biopotential Input range∓2 mV ∓2 mV   
    Biopotential Resolution12 bit A/D 12 bit A/D   
    Biopotential High pass characteristicsAC coupled, single pole, -3dB point at 0.7 Hz AC coupled, single pole, -3dB point at 0.7 Hz   
    Biopotential lead wires25 cm length, coiled stainless steel (1 pair)25 cm length, coiled stainless steel (2 pairs) 25 cm length, coiled stainless steel (1 pair)   
    Biopotential lead wire diameter1 mm 1 mm   
    CalibrationPrecalibrated
    Analog output calibration valuesBiopotential: 2V output = 0mV input, 4V output = 2 mV input Temperature: 0V output = 0℃, 1V output = 20℃Pressure: 1V output - 0mmHg, 2V output = 100 mmHg Temperature: 0V output = 0℃, 1V output = 20℃Pressure: 1V output - 0mmHg, 2V output = 100 mmHg Biopotential: 2V output = 0mV input, 4V output = 2 mV input Temperature: 0V output = 0℃, 1V output = 20℃Pressure: 1V output - 0mmHg, 2V output = 100 mmHg Temperature: 0V output = 0℃, 1V output = 20℃Pressure: 1V output - 0mmHg, 2V output = 100 mmHg SNA: 2V output - 0 µV input, 4V output = 60 µV input Temperature: 0V output = 0℃, 1V output = 20℃Oxygen: 1V output - 0nA, 2V output = -200nA Temperature: 0V output = 0℃, 1V output = 20℃
    Pressure sensor accuracy  ∓2 mmHg 
    Pressure sensor drift  <4 mmHg per month 
    Pressure sensor Frequency response  DC to 500 Hz (-3 dB) 
    Standard pressure catheter dimensions  Distal tip; 660 µm OD (2Fr), Catheter; 500 µm (1.5Fr), length 9cm (15 & 25 cm options available for all except TRM56SP) 
    Pressure sensor range  -40 to 300 mmHg @ atm of 760 mmHg (720 to 1060 mmHg absolute pressure) 
    Ambient pressure range  650 to 800 mmHg 
    Maximum operating altitude  1300 m 
    SNA Input range     ∓60 µV 
    SNA High pass filter     -3dB point at 1.5 Hz 
    SNA Input impedance     500 kOhms at 1000 Hz 
    SNA lead wires     Multi-stranded stainless steel (length 25cm) 
    SNA lead wire diameter     0.15 mm (wire only) 
    Potentiostat type     Voltage controlled current source 
    Set potential     -0.65V (-650mV) 
    Potentiostat current measurement range     0 to -600nA 
    Potentiostat resolution     12 bit A/D 
    Potentiostat lead wires     Coiled stainless steel (~28cm) 
    Potentiostat wire diameter     1 mm 

    Product Codes

    TR50B
    Biopotential Telemeter (ECG, EEG, EMG)
    TR50BB
    Dual Biopotential Telemeter (ECG, EEG and/or EMG)
    TRM54P
    Pressure Telemeter
    TRM54PB
    Pressure Biopotential Telemeter
    TRM54PP
    Dual Pressure Telemeter
    TRM56SP
    SNA and Pressure Telemeter
    TR57Y
    Tissue Oxygen Telemeter