LabChart Support

Beginners Guide to using LabChart

If you don't already have a license but want to try it out, request a demo licence

 

Licensing Information

LabChart 8 offers a range of data recording and analysis or analysis only licence options. Find out more.

 

Getting Started

Within the Welcome Centre of LabChart, you will be provided with a helpful getting started Tutorial with tips and tricks to help get you up and running quickly.

Get a quick overview now

Take it to the next level

  • Expand and deepen your knowledge of data acquisition and analysis with LabChart 8 through our online training course. Find out more

LabChart Videos

Filter videos

LabChart Version

GLP Software for LabChart

LabChart Add-Ons

info The easiest way to install Add-Ons is via LabChart's Feature Manager.

Services and training

Our range of interactive, hands-on courses and workshops reduce on-boarding time, and work to increase efficiency and output, helping you achieve your education and research aims, faster.

Online Training Course

Expand and deepen your knowledge of data acquisition and analysis with LabChart 8 through our online training course.

 

An ideal resource for those wishing to learn in their own time and pace, or looking for an option to train lab staff when social distancing is in place. This course is an online version of our 2-day in person training option via our own active learning educational platform, Lt. Course content includes:

  • Data acquisition basics
  • Filtering and smoothing
  • Using Chart, Scope and Spectrum Views
  • Advanced analysis features, such as Macros and Arithmetic
  • Training on each of the LabChart Pro advanced modules

A comprehensive and interactive way to unlock the meaning of your data.

Each lesson contains:

  • Learning objectives
  • Technique / feature overviews
  • Video-directed exercises with demo files
  • Interactive questions and answers

This option is currently available in North America, South America, UK, and the EU. If you are interested in further details or access to this course, please fill out the form below and we will be in touch.

Show releases for:

LabChart 8.1.5 (Windows)

General

LabChart is now fully compatible with Windows 10 Anniversary Update.

LabChart Known Issues

Windows

  • LabChart 8.1 or later do not support Windows Classic theme.
  • In the Preset Comment "Event Configuration" dialog, if "Comment only on first stimulus" is checked, the comment is disabled for the entire record after the first pulse.

Mac

  • If you are on OS X v10.11 (El Capitan) and have already upgraded to LabChart 8.1.2 - Please upgrade to 8.1.3 here on our website rather than in feature manager. You can then proceed as normal for all future upgrades.
  • There are some features that were present in LabChart 7 that are not currently included in LabChart v8.1. Click here for more information.
  • The ADInstruments Blood Flow Meter is occasionally initialized with only one channel enabled. The user can manually enable the second channel.
  • For machines that have high-resolution Retina displays, users may encounter responsiveness and stability issues when using the Scope View.

LabChart 8.1.9

Mac and Windows

General

  • While recording, comments can now be moved without issue.
  • Arithmetic variables can now be used in Arithmetic channel calculations on systems that use European region localisation.
  • Fixed an issue where Scope pages names were forgotten in certain saved files.
  • Fixed issue where the Stimulator could produce an extra half cycle beyond the number of cycles requested, at some frequencies, such as 500 Hz.
  • In order to assist with data recovery in situations where a saved data file is lost or damaged, a fixed number of the most recently recorded data files are now retained as backup.
  • Fixed an issue affecting documents recovered via disk buffer recovery. LabChart now prompts the user to save the file when LabChart is closed.

Windows

General

  • Fixed several instances of incorrect wording relating to the Spectrum feature with Japanese and Chinese versions of LabChart.
  • While recording, Scope in comment mode now updates immediately to show the correct list of pages each time a comment is deleted.
  • The list of recently opened files in the Welcome Center and File menu now updates immediately when a file is closed.
  • Fixed an issue preventing use of milliseconds as the time unit for Max Repeat Rate within the Stimulator panel if the Isolated Stimulator is being used.
  • The Isolated Stimulator Current parameter can now be adjusted in increments that are multiples of 0.1 mA. Previously, it was limited to being multiples of 0.2.
  • Fixed a LabChart stability issue when increasing channel count and applying channel calculations from within the Channel Settings dialog.
  • Fixed a usability issue affecting renaming Scope pages.

Improvements

  • A new "File Name" Data Pad function is available under the Block Information section in the Data Pad Column Setup Dialog which returns the name of the file containing the current selection.

Mac

General

  • The data scale in the Input Amplifier dialog now correctly adjusts as the hardware range is changed.
  • Fixed an issue when entering a fixed duration in milliseconds within the Sampling Dialog.
  • When modifying an existing units conversion, LabChart now always looks at the underlying raw data.

LabChart 8.0.6 (Windows)

General

  • The Simple Data File SDK bundled with LabChart now supports both 32 bit and 64 bit programs that can read and write LabChart files.
  • Japanese and Chinese versions have improved interface layout and translations.
  • Improved the display of data in the Units Conversion dialog when the current file contains data with channels recorded at different rates.

Channel Calculations

  • Improved the accuracy of the Spectral Edge Frequency Data Pad and Channel Calculations.
  • Improved reliability when sampling many short blocks using event related Channel Calculations.

Chart and Scope View

  • Chart View now displays sampling speed and gain ranges when the mouse is over the right-hand parameters region.
  • Improved reliability when editing comments in the Chart View.
  • Improved behavior when sampling with two documents open to ensure the Start and Stop buttons display correctly in each document.
  • The maximum allowed time compression for the Chart and Scope Views has been increased to 500k:1.
  • Saving as ADIDAT now supports saving the Chart View selection range. This is the same behavior as Saving as ADICHT.
  • Improved reliability when using Multiple Add to Data Pad to add data using comments on an averaged page in Scope View.

Sampling

  • Added support for documents to be opened (or created) while another LabChart document is sampling.
  • Improved behavior when the default Stimulator settings are used to ensure the Stimulator starts at the start of each new block in repetitive fixed duration sampling mode.

Export

  • Export As Axon no longer shows an error message when "All" is selected in the Channels drop-list of the dialog.
  • Improved scaling of data by Export As Axon for channels where the range has been changed between blocks.
  • Export As Axon now saves comments in the correct positions when multiple channels are saved.

LabChart 8.0.9 (Mac)

General

  • Improved Arithmetic's handling of certain expressions that make use of event channels (such as when the output of Cyclic Measurements is used).
  • The Input Amplifier Dialog in LabChart for Mac now always displays the same default settings in a new document as Windows.

Channel Settings Dialog

The Units Conversion dialog options are now always enabled as appropriate when accessed from the Channel settings dialog.

LabChart 8.1.1 (Mac)

LabChart is now compatible with Mac OS X 10.11 El Capitan.

LabChart 8.1.3 (Windows)

Export

When exporting a selection to IGOR, users can now export comments.

Data Pad

Various improvements have been made to editing formulae and entering data in the Data Pad.

Japanese

Various corrections have been made to the Japanese translations.

LabChart 8.1.7 and 8.1.8 (Windows)

General

  • Fixed an issue where some views couldn’t be copy-and-pasted into other applications.
  • Stimulator interval can now be specified in milliseconds.
  • Fixed an issue where the input amplifier dialog would reset its scale to default after any setting was changed.
  • Fixed an issue where Data Pad’s channel value calculations were sometimes out by a constant factor. This could happen when making selections in the Scope view and a background page had been specified.
  • Fixed issue where Bioamp Dialog could display combinations of Low pass and High pass filter settings that were not supported by the hardware.
  • Updated Trigger help to mention limitations of Stimulator event triggers
  • When deleting data in the Chart View, there is now an option to set the start of the block time to 0.
  • Fixed issue where DataPad calculations in columns beyond 'BL' would display 'Calculating...' indefinitely and not display a result.
  • Fixed an issue affecting the display of the LabChart Logo in Welcome Centre
  • Added a new CopyEx macro command which has an option to suppress the convert to text dialog, making it easier to automate exporting data from LabChart via macros.
  • Update Stimulator help FAQ to mention using Interval instead of Max Repeat Rate
  • Fixed error message that would occur when importing macros from files saved with LabChart 8.1 or later.
  • Minor fixes to wording in Japanese and Chinese translated versions of LabChart
  • Fixed an issue where the SetCommentText macro command renames the incorrect comment.
  • Improved the macro commands for adding new comments: the constant kAllChannels can now be used for the channel index parameter to add a comment across all channels.
  • Fixed an occasional usability issue issue when attempting to relocate the marker..
  • Fixed an issue where the right pane of the Welcome Centre would sometimes open a different folder than the user had clicked.
  • Fixed right-clicking to add a comment in the Zoom View.
  • You can now set the number of decimal places from the Spectrum channel calculation dialog.
  • Calculated channel data is now correctly shown if present when sampling in the Arithmetic or Cyclic Measurements calculation dialogs.
  • Fixed issue where clicking on the marker home while sampling could result in issues with the display of data or the graticule..

LabChart 8.0.4 (Windows)

General

  • Improvements have been made to the layout of dialogs for enhanced readability in Chinese and Japanese versions of LabChart.
  • Files saved from LabChart 8.0.4 correctly preserve input amplifier settings when opened under LabChart 7 (v7.3 or later).

Channel Settings Dialog

The channel colors displayed in the Channel Settings dialog now always match the colors of the actual drawn data.

Sampling

  • Improved behavior while waiting for devices to finish producing data after user clicks the stop sampling button.
  • Synchronization between multiple sampling devices has been improved for multi-rate sampling when rates are greater than 1000 Hz.

Macros

  • Improved reliability when importing macros containing custom shortcut key assignments
  • The Extras folder (which is located in LabChart's installation location) now includes an example VBScript file showing how supported LabChart events can be handled from an external script.

Scope View

Improved reliability when a file is opened that has a Scope event source, when the module that previously provided the event source (such as Peak Analysis) is no longer present.

LabChart 8.0.8 (Windows)

General

  • Users can now edit or setup a new units conversion in the Units Conversion dialog without a PowerLab connected in Analysis mode.
  • Improved stability when opening the Input Amplifier for the FE141 Spirometer when it is connected to a PowerLab input 5 or higher.
  • Improved behavior to ensure GLP documents can be opened and saved correctly.
  • Improved the behavior and display of the sampling buttons in the PV Loop workflow.
  • Improved stability when error messages are triggered.
  • Improved consistency of channel information icons when another document is sampling.
  • Reading text files with empty data columns now fills those columns with zeroes rather than the value 1.024.

Welcome Center

Welcome Center folders are no longer shown when all of their files are explicitly hidden in labels.ini (for example, Instructors Reference folders in the LabChart Experiments).

Data Pad

  • Improved Data Pad Plots Quadratic fit to ensure correct results are consistently produced.
  • Improved stability when the Data Pad Median function is applied to a channel containing no data.
  • Adding to Data Pad no longer causes a Document Write error on attempting to save the document under certain conditions.

Channel Calculations

  • The Cyclic Measurements "Customize" dialog is now prevented from being opened repetitively in an infinite loop by Timed Add to Data Pad.
  • Improved reliability of error reporting to ensure false errors are not triggered by Arithmetic about an "incompatible source" when using a channel containing event data as a source to an expression expecting event data.

Chart and Scope View

  • Clicking and dragging a selection in the Chart or Scope Views now correctly updates the time and recorded values at the cursor position as the selection is being made.
  • The "Units" button in the Input Amplifier dialog in the LabChart Chart View channel calculations menu now correctly sets a unit conversion in the Chart View as well as in the Input Amplifier preview.
  • Improved the behavior of selections in both Chart and Scope View when the mouse buttons are swapped over (in Control Panel Mouse Options).

Sampling

  • Bio Amps now correctly show a 60 Hz notch filter option (rather than 50 Hz) in the Input Amplifier in countries using a 60 Hz mains frequency.
  • Improved stability after the number of channels in a document is changed while another document is sampling.

Preset Comments

Preset Comments now show the correct #W pulse width in a comment for custom user profiles.